Microsoft Windows Event ID and SNMP Traps Reference Guide for use with SmartStart version 8.25

Server agents 116
NT Event ID: 1166 (Hex)0xc435048e (cpqsvmsg.dll)
Log Severity: Error (3)
Event Title: Inadequate Power To Power On
Log Message: There is not enough power to power on the server blade. The server enclosure micro-
controller was not found.
SNMP Trap: cpqRackServerPowerOnFailedEnclosureNotFound - 22024 in CPQRACK.MIB
Symptom: Inadequate power to power on. There is not enough power to power on the server blade.
The server enclosure micro-controller was not found.
User Action: Check server enclosure connections or add power supplies.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqRackName
cpqRackUid
cpqRackServerBladeEnclosureName
cpqRackServerBladePosition
cpqRackServerBladeSparePartNumber
cpqRackCommonEnclosureSerialNum
cpqRackCommonEnclosureTrapSequenceNum
Supporting SNMP Trap Description: “Inadequate power to power on blade
[cpqRackServerBladePosition], in enclosure [cpqRackServerBladeEnclosureName], in rack
[cpqRackName].”
NT Event ID: 1167 (Hex)0xc435048f (cpqsvmsg.dll)
Log Severity: Error (3)
Event Title: Inadequate Power To Power On
Log Message: There is not enough power to power on the server blade. The power enclosure micro-
controller was not found.
SNMP Trap: cpqRackServerPowerOnFailedPowerChassisNotFound - 22025 in CPQRACK.MIB
Symptom: Inadequate power to power on. There is not enough power to power on the server blade.
The power enclosure micro-controller was not found.
User Action: Check power enclosure connections or add power supplies.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqRackName
cpqRackUid
cpqRackServerBladeEnclosureName
cpqRackServerBladePosition
cpqRackServerBladeSparePartNumber
cpqRackCommonEnclosureSerialNum