Table 2 Information provided by Agentless Management and Insight Management Agents
Insight Management Agents
1, 2
Agentless Management with
AMS
1
Agentless Management without
AMS
1
Component
Server health
Fans Fans Fans
Temperatures TemperaturesTemperatures
Power suppliesPower supplies Power supplies
MemoryMemoryMemory
CPU CPUCPU
Storage
Smart Array Smart Array
3
Smart Array
3
SMART Drive Monitoring
(connected to Smart Array)
SMART Drive Monitoring
(connected to Smart Array,
Smart HBA, and AHCI)
SMART Drive Monitoring
(connected to Smart Array,
Smart HBA, and AHCI)
Internal and external drives
connected to Smart Array SAS/SATA HBA/RAIDInternal and external drives
connected to Smart Array
Smart Storage battery
monitoring (supported servers
only)
Fibre Channel/iSCSI
Smart Storage battery
monitoring (supported servers
only)
Tape
External storage
NVMe drives
4
Network
MAC and IP addresses for
standup and embedded NICs
MAC and IP address for
standup and embedded NICs
MAC addresses for embedded
NICs
Physical link connectivity and
link up/link down traps for NICs
that have NC-SI over MCTP
Link up/link down trapsLink up/link down traps
6
NIC teaming information NIC teaming information
VLAN informationSupported Fibre Channel
adapters
Fibre Channel adapters that
support Hewlett Packard
Enterprise vendor-defined
MCTP commands
5
Other
iLO data iLO data iLO data
Firmware inventory OS information (host SNMP
MIB)
Firmware inventory
Device inventoryDevice inventory
Performance data
OS information (host SNMP
MIB)
6
User-configurable thresholds
Logging events to OS logs
Driver/service inventory
Clustering information
Logging events to OS logs
7
Prefailure warranty
alerts
Memory Memory Memory
Drives (physical and logical) Drives (physical and logical)Drives (physical and logical)
1
The Agentless Management without AMS column represents the basic iLO configuration without AMS or the Insight Management
Agents. Server configurations with AMS or the Insight Management Agents provide the same information as the basic iLO
configuration, as well as the information that is listed in the Agentless Management with AMS and Insight Management Agents
columns.
2
Supported servers only. For more information, see the server specifications.
3
This configuration does not write the same OS logs as the Insight Management Agents. For example, RAID device status is not
reported.
4
Supported with iLO 4 2.30 and later.
5
Supported with iLO 4 2.50 and later.
iLO SNMP management 113