Installation Manual
Table 3 SNMP traps
DescriptionSNMP trap name
SNMP has been initialized, the system has completed
POST, or AMS has started.
Cold Start Trap 0
SNMP has detected an authentication failure.Authentication Failure Trap 4
An uncorrectable machine check exception has been
detected in a processor.
cpqSeCpuStatusChange 1006
A read error occurred on an attached USB storage device.cpqSeUSBStorageDeviceReadErrorOccurred 1010
A write error occurred on an attached USB storage device.cpqSeUSBStorageDeviceWriteErrorOccurred 1011
USB storage device redundancy was lost.cpqSeUSBStorageDeviceRedundancyLost 1012
USB storage device redundancy was restored.cpqSeUSBStorageDeviceRedundancyRestored 1013
The sync operation to restore USB storage device
redundancy failed.
cpqSeUSBStorageDeviceSyncFailed 1014
A change has been detected in the status of the Smart
Array controller.
cpqDa6CntlrStatusChange 3033
A change has been detected in the status of a Smart Array
logical drive.
cpqDa6LogDrvStatusChange 3034
A change has been detected in the status of a Smart Array
cache module.
cpqDa6AccelStatusChange 3038
The Smart Array cache module has lost backup power.cpqDa6AccelBadDataTrap 3039
The Smart Array cache module backup power has failed.cpqDa6AccelBatteryFailed 3040
A change has been detected in the status of a Smart Array
physical drive.
cpqDa7PhyDrvStatusChange 3046
A change has been detected in the status of a Smart Array
spare drive.
cpqDa7SpareStatusChange 3047
A change has been detected in the SSD wear status of
a Smart Array physical drive.
cpqDaPhyDrvSSDWearStatusChange 3049
The server was shut down due to a thermal anomaly and
is now operational.
cpqHe3ThermalConfirmation 6026
One or more POST errors have occurred.cpqHe3PostError 6027
The fault-tolerant power supplies have lost redundancy
for the specified chassis.
cpqHe3FltTolPowerRedundancyLost 6032
A fault-tolerant power supply has been inserted.cpqHe3FltTolPowerSupplyInserted 6033
A fault-tolerant power supply has been removed.cpqHe3FltTolPowerSupplyRemoved 6034
The fault-tolerant fan condition has been set to Degraded.cpqHe3FltTolFanDegraded 6035
The fault-tolerant fan condition has been set to Failed.cpqHe3FltTolFanFailed 6036
The fault-tolerant fans have lost redundancy.cpqHe3FltTolFanRedundancyLost 6037
A fault-tolerant fan has been inserted.cpqHe3FltTolFanInserted 6038
A fault-tolerant fan has been removed.cpqHe3FltTolFanRemoved 6039
The temperature status has been set to Degraded, and
the temperature is outside the normal operating range.
cpqHe3TemperatureDegraded 6041
Depending on the system configuration, this system might
be shut down.
122 Configuring iLO management settings