Installation Manual

Table 3 SNMP traps (continued)
DescriptionSNMP trap name
The temperature status has been set to OK.cpqHe3TemperatureOk 6042
The fault-tolerant power supply condition has been reset
to OK.
cpqHe4FltTolPowerSupplyOk 6048
The fault-tolerant power supply condition has been set to
Degraded.
cpqHe4FltTolPowerSupplyDegraded 6049
The fault-tolerant power supply condition has been set to
Failed.
cpqHe4FltTolPowerSupplyFailed 6050
The Advanced Memory Protection subsystem has
detected a memory fault. Mirrored Memory has been
activated.
cpqHeResilientMemMirroredMemoryEngaged 6051
The fault-tolerant power supplies have returned to a
redundant state.
cpqHe3FltTolPowerRedundancyRestore 6054
The fault-tolerant fans have returned to a redundant state.cpqHe3FltTolFanRedundancyRestored 6055
Memory errors have been corrected. Replace the memory
module.
cpqHe5CorrMemReplaceMemModule 6064
The fault-tolerant power supply in the specified chassis
and bay reported AC power loss.
cpqHe4FltTolPowerSupplyACpowerloss 6069
The HPE Smart Storage Battery has failed.cpqHeSysBatteryFailed 6070
The HPE Smart Storage Battery has been removed.cpqHeSysBatteryRemoved 6071
iLO could not determine the power requirements. The
server power allocation is not optimized.
cpqHeSysPwrAllocationNotOptimized 6072
The server could not power on because the hardware
cannot be identified.
cpqHeSysPwrOnDenied 6073
A device power failure has been detected.cpqHePowerFailureError 6074
A device is missing or improperly seated on the system
board.
cpqHeInterlockFailureError 6075
The storage enclosure fan status changed.cpqSs6FanStatusChange 8029
The storage enclosure temperature status changed.cpqSs6TempStatusChange 8030
The storage enclosure power status changed.cpqSs6PwrSupplyStatusChange 8031
The storage enclosure status changed.cpqSsConnectionStatusChange 8032
The server power has been reset.cpqSm2ServerReset 9001
The maximum unauthorized login attempt threshold has
been exceeded.
cpqSm2UnauthorizedLoginAttempts 9003
iLO 4 has detected a self test error.cpqSm2SelfTestError 9005
iLO 4 has detected that the security override jumper has
been toggled to the engaged position.
cpqSm2SecurityOverrideEngaged 9012
iLO 4 has detected that the security override jumper has
been toggled to the disengaged position.
cpqSm2SecurityOverrideDisengaged 9013
The server has been powered on.cpqSm2ServerPowerOn 9017
The server has been powered off.cpqSm2ServerPowerOff 9018
A request was made to power on the server, but the server
could not be powered on because of a failure condition.
cpqSm2ServerPowerOnFailure 9019
SNMP traps 123