Installation Manual
Additional policies are implemented after an excessive temperature condition is corrected,
including returning the fan speed to normal, recording the event in the IML, turning off the LED
indicators, and canceling shutdowns in progress (if applicable).
Viewing power information
Navigate to the Information→System Information page, and then click the Power tab.
The information displayed on the Power Information page varies depending on the server type.
• Nonblade servers (DL, ML)—The page displays the following sections: Power Supply
Summary, Power Supplies, HPE Power Discovery Services (if available), and Smart
Storage Battery (supported servers only).
• Nonblade servers (SL, XL)—The page displays the following section: Power Supply
Summary.
More power information is displayed on the Chassis Information page. For more information,
see “Viewing chassis information” (page 259).
• Server blades and Synergy compute modules—The page displays the following sections:
Power Readings, Power Microcontroller, and Smart Storage Battery (supported servers
only).
If the server is powered off, the system health information on this page is current as of the last
power off. Health information is updated only when the server is powered on and POST is
complete.
Power Supply Summary details
Present Power Reading
When HPE Common Slot Power Supplies are present, the most recent power reading from the
server is displayed. Other power supplies do not provide this data.
Although this value is typically equal to the sum of all active power supply outputs, there might
be some small variance as a result of reading the individual power supplies. This value is a
guideline value and is not as accurate as the values presented on the Power Management
pages. For more information, see “Viewing server power usage” (page 249).
Power Management Controller Firmware Version
The firmware version of the power management controller. The server must be powered on for
the iLO firmware to determine this value. This feature is not available on all servers.
Power Status
The overall status of the power supplied to the server.
• If the server power supplies are connected to a nonintelligent power source, this section
displays the status of the internal server power supplies.
• If the server power supplies are connected to Power Discovery Services through an iPDU,
this section displays the status of the power supplied to the internal server power supplies.
158 Viewing iLO overview and system information