Installation Manual

Power Supplies list
Some power supplies do not provide information for all of the values in this list. If a power supply
does not provide information for a value, N/A is displayed.
Bay
The power supply bay number.
Present
Indicates whether a power supply is installed. The possible values are OK and Not Installed.
Status
The power supply status. The displayed value includes a status icon (OK, Degraded, Failed, or
Other), and text that provides more information. The possible values follow:
Unknown
Good, In Use
Good, Standby
General Failure
Over Voltage Failure
Over Current Failure
Over Temperature Failure
Input Voltage Lost
Fan Failure
High Input A/C Warning
Low Input A/C Warning
High Output Warning
Low Output Warning
Inlet Temperature Warning
Internal Temperature Warning
High Vaux Warning
Low Vaux Warning
Mismatched Power Supplies
PDS
Whether the installed power supply is enabled for Power Discovery Services.
Hotplug
Whether the power supply bay supports swapping the power supply when the server is powered
on. If the value is Yes, and the power supplies are redundant, the power supply can be removed
or replaced when the server is powered on.
160 Viewing iLO overview and system information