Installation Manual
Power Supplies list
Some power supplies do not provide information for all of the values in this list. If a power supply
does not provide information for a value, N/A is displayed.
Bay
The power supply bay number.
Present
Indicates whether a power supply is installed. The possible values are OK and Not Installed.
Status
The power supply status. The displayed value includes a status icon (OK, Degraded, Failed, or
Other), and text that provides more information. The possible values follow:
• Unknown
• Good, In Use
• Good, Standby
• General Failure
• Over Voltage Failure
• Over Current Failure
• Over Temperature Failure
• Input Voltage Lost
• Fan Failure
• High Input A/C Warning
• Low Input A/C Warning
• High Output Warning
• Low Output Warning
• Inlet Temperature Warning
• Internal Temperature Warning
• High Vaux Warning
• Low Vaux Warning
• Mismatched Power Supplies
PDS
Whether the installed power supply is enabled for Power Discovery Services.
Hotplug
Whether the power supply bay supports swapping the power supply when the server is powered
on. If the value is Yes, and the power supplies are redundant, the power supply can be removed
or replaced when the server is powered on.
160 Viewing iLO overview and system information