Installation Manual

Supported storage components
The Storage Information page displays information about the following storage components:
Smart Array controllers, drive enclosures, the attached logical drives, and the physical drives
that constitute the logical drives.
Hewlett Packard Enterprise and third-party storage controllers that manage direct-attached
storage, and the attached physical drives.
iLO 4 2.10 and later supports the following products:
HPE ML/DL Server M.2 SSD Enablement Kit
HPE 12G SAS Expander
HPE Dual 8GB MicroSD EM USB Kit
iLO 4 2.30 and later supports the following product:
NVMe drives
Smart Array controllers are listed first on the page, followed by other Hewlett Packard Enterprise
and third-party storage controllers.
Smart Array details
iLO displays information about the following:
Controllers
Drive enclosures
Logical drives
Physical drives
iLO can monitor 71 physical drives on a controller, 256 physical drives total, and 256 logical
drives total.
Controllers
This section provides the following details for each Smart Array controller.
Controller location—Slot number or system board
Top-level controller status—The top-level controller status (displayed on the left of the
controller location) is a combination of the controller hardware status and the status of cache
modules, enclosures, and physical, logical, and spare drives associated with the controller.
If the controller hardware status is OK, and any associated hardware has a failure, the
174 Viewing iLO overview and system information