Installation Manual

top-level controller status changes to Major Warning or Degraded, depending on the failure
type. If the controller hardware has a Failed status, the top-level controller status is Failed.
Controller Status—Controller hardware status (OK or Failed)
Serial Number
Model
Firmware Version
Controller Type
Cache Module Status
Cache Module Serial Number
Cache Module Memory
Encryption Status—Indicates whether encryption is enabled in the controller.
The following values are possible:
Enabled
Not Enabled
Enabled—Local Mode—This value is displayed when you do not use a remote key
management server.
Encryption ASIC Status—Indicates whether the ASIC encryption self tests for the controller
passed or failed. A failed status indicates that the controller is not encrypted.
Encryption Critical Security Parameter NVRAM Status—Indicates whether the controller
successfully detected the critical security parameter NVRAM. A failed status means that the
controller is not encrypted.
The encryption settings for a Smart Array controller can be configured by using the Smart Storage
Administrator software.
Drive Enclosures
This section provides the following information about the drive enclosures attached to a Smart
Array controller.
Enclosure port and box numbers
Status
Drive Bays—The number of drive bays
Serial Number
Model
Firmware Version
Some enclosures do not have all of the listed properties, and some storage configurations do
not have drive enclosures.
Viewing storage information 175