Installation Manual
Power-On Delay settings
On supported servers, choose from the following Power-On delay settings:
• Minimum Delay—Power-on occurs after iLO startup is complete.
• 15 Second Delay—Power-on is delayed by 15 seconds.
• 30 Second Delay—Power-on is delayed by 30 seconds.
• 45 Second Delay—Power-on is delayed by 45 seconds.
• 60 Second Delay—Power-on is delayed by 60 seconds.
• Random up to 120 seconds—The power-on delay varies and can be up to 120 seconds.
Viewing server power usage
Navigate to the Power Management→Power Meter page.
The Power Meter page enables you to view the server power consumption over time.
This feature and many others are part of an iLO licensing package. For more information, see
the following website: http://www.hpe.com/info/ilo/licensing.
Power meter graph details
The power-meter graphs display recent server power usage. The graph data is reset when iLO
or the server is reset. The iLO firmware periodically samples peak power, average power, and
power cap. The following graphs are displayed:
• 24-Hour History Graph—Displays the power usage of the server over the previous 24
hours. The iLO firmware collects power usage information from the server every 5 minutes.
Viewing server power usage 249