Specification Sheet
QuickSpecs
HP ProLiant DL360p Generation 8 (Gen8)
Technical Specifications
c04123167 – DA – 14211 Worldwide — Version 64 — September 28, 2015
Page 62
System Unit
Dimensions (H x W x D)
8 SFF and 10 SFF
1.7 x 17.1 x 27.5 inches (4.32 x 43.47 x
69.85 cm)
4 LFF
1.7 x 17.1 x 29.5 inches (4.32 x 43.47 x
74.67 cm)
Weight (approximate)
Maximum
(all hard drives, power supply,
and processor installed)
8 SFF
42.3 lb (19.2 kg)
10 SFF
42.3 lb (19.2 kg)
4 LFF
45.6 lb (20.7 kg)
Minimum
(one hard drive, power supply,
and processor installed)
32 lb (14.51 kg)
Input Requirements
(per power supply)
Rated Line Voltage
100 to 120 VAC
200 to 240 VAC
Rated Input Current
4.5 Amps (at 120VAC) to 2.2 Amps (at 240
VAC)
Rated Input Frequency
50 to 60 Hz
BTU Rating
Maximum
1773 BTU / hr (at 120 VAC), 1715 (at 240
VAC)
Power Supply Output
(per power supply)
Rated Steady-State Power
460 W (at 100 to 120 VAC),
460 W (at 200 to 240 VAC)
750 W (at 100 to 120 VAC),
750 W (at 200 to 240 VAC)
Maximum Peak Power
460 W (at 100 to 120 VAC),
460 W (at 200 to 240 VAC)
750 W (at 100 to 120 VAC),
750 W (at 200 to 240 VAC)
System Inlet
Temperature
Operating
10° to 35°C (50° to 95°F) at sea level with an
altitude derating of 1.0°C per every 304.8 m
(1.8°F per every 1000 ft) above sea level to a
maximum of 3048 m (10,000 ft), no direct
sustained sunlight. Maximum rate of change
is 10°C/hr (18°F/hr). The upper limit may be
limited by the type and number of options
installed.
System performance may be reduced if
operating with a fan fault or above 30°C
(86°F).
Non-operating
-30° to 60°C (-22° to 140°F). Maximum rate
of change is 20°C/hr (36°F/hr).
Relative Humidity
(non-condensing)
Operating
10 to 90% relative humidity (Rh), 28°C
(82.4°F) maximum wet bulb temperature,
non-condensing.
Non-operating
5 to 95% relative humidity (Rh), 38.7°C
(101.7°F) maximum wet bulb temperature,
non-condensing.
Altitude
Operating
3048 m (10,000 ft). This value may be
limited by the type and number of options
installed. Maximum allowable altitude
change rate is 457 m/min (1500 ft/min).
Non-operating
9144 m (30,000 ft). Maximum allowable
altitude change rate is 457 m/min (1500
Retired