HP ProLiant DL360p Gen8 Carrier-Grade Server Read Before Install Carrier-Grade Instructions

4 Changing the Settings on the System Maintenance Switch
WARNING! To prevent personal injury from hazardous energy, remove watches, rings, or other
metal objects.
Preventing Electrostatic Discharge
To prevent damage to the system, you must take precautions when setting up the system or the
handling of parts. A discharge of static electricity from a finger or other conductor might damage
system boards or other static sensitive devices. This type of damage can reduce the life expectancy
of the device.
To prevent electrostatic damage, practice the following precautions:
Avoid hand contact by transporting and storing parts in static-safe containers.
Keep electrostatic-sensitive parts in containers until they arrive at static-free workstations.
Before removing parts from containers, place parts on a grounded surface.
Avoid touching pins, leads, or circuitry.
Ensure you are properly grounded when touching a static-sensitive component or assembly.
To change the settings on the system maintenance switch:
1. Power off the server.
2. Remove power to the server.
3. Remove the top cover.
4. Locate the system maintenance switch. When viewed from the front of the server, the switch
is located at the rear of the system board on the right side.
See the following graphic illustration:
5. Select the system maintenance switch, the ID is SW2, and change position #10 to the ON
position. You can use a plastic ball-point pen to flip the system maintenance switch.
6. Replace the top cover.
8 Changing the Settings on the System Maintenance Switch