HP ProLiant DL360p Gen8 Carrier-Grade Server Read Before Install Carrier-Grade Instructions
Verifying the System Maintenance Switch Setting
After you switch the setting, you must verify that position #10 on the system maintenance switch
is in the ON position.
NOTE: The following instructions which verify the thresholds are correct, use HP Integrity iLO4.
For complete information and instructions using iLO4, see the HP iLO 4 User Guide at the following
HP website:
http://www.hp.com/go/ilo/docs
1. Log in to iLO4. For instructions, see the HP Integrated Lights-Out 4 User Guide.
2. Select System Information on the left navigation bar.
3. Select the Temperatures tab.
If the temperature thresholds of sensor 01–Inlet Ambient appear as shown below, the
switch is set correctly.
Incorrect Thresholds
If the thresholds do not show up correctly, ensure the #10 position was set correctly. If incorrectly
set, reset the system maintenance switch SW2 to the factory defaults as described in the HP Proliant
DL360p Gen8 Server Maintenance and Service Guide at the following HP website:
http://www.hp.com/go/hpsc
Enter a product name, or select Servers, and then selectProliant /tc series servers. Select your
product, and then click Manuals under Knowledge Base. You may need to click through more than
one page of manuals to find a specific one.
After you reset the switch settings to the factory defaults, repeat the procedure above on how to
verify the system maintenance switch setting.
Verifying the System Maintenance Switch Setting 9