HP Smart Update Manager 6.4.1 Release Notes
HP SUM displays an error when it inventories WBEM and FCHBA components on VMware nodes
Suggested Action: No action. This indicates that the VMware WBEM provider might be stopped or
hung.
HP SUM displays “Update returned an error” when deploying the HP ProLiant Converged Network
Utility for Windows 2008 (component cp022111.exe)
Suggested Action: No action. This will be resolved in a future version.
HP SUM stops responding when it attempts to deploy component cp020538.exe
Suggested Action: No action. Deploy this component outside of HP SUM.
HP SUM stops responding when you type a baseline address
Suggested Action: If this happens, use the browse button to navigate to a baseline directory.
Deploying updates to OA and iLO nodes at the same time might cause a network issue
Suggested Action: Deploy updates to the iLO and OA through the OA node. HP SUM determines the
proper deployment order to minimize deployment issues. Alternatively, you can wait for HP SUM to
finish updating one node and then update the other node.
HP SUM requires minimum versions of VC and OA to support HP Integrity nodes
Suggested Action: Verify that HP Integrity i2 OA versions are 3.30 and VC version 3.6, and HP Integrity
i4 servers are OA version 3.60 and VC version 3.70.
HP SUM displays only one enclosure for Superdome2 nodes
Suggested Action: HP SUM does not display enclosure 2 unassigned blades, HP SUM displays partitions
of the blades. You can update all nodes from the GUI by selecting all nodes. In the CLI or interactive
CLI you can update the unassigned blades by including them in the device list.
HP SUM does not deploy updates to a VC node that is managed by VCEM
Suggested Action: No action. Use VCEM to deploy updates to the VC node.
HP SUM does not inventory or deploy all nodes when you select multiple nodes when using the GUI
Suggested Action: Re-inventory or re-deploy on the nodes that did not finish. It is recommended that
you inventory or deploy 10 or fewer nodes at a time when using HP SUM at this time. This will be
resolved in the future version of HP SUM.
HP SUM does not install iLO firmware updates when TPM is active
HP SUM does not detect if TPM is active before deploying updates to an iLO node.
Suggested Action: Disable TPM if HP SUM does not apply iLO updates.
HP SUM displays a message that the firmware of Hard Disk Drives behind an HP Smart Array
H220/H222 controller is already updated when the firmware component is deployed online
Suggested Action: Updating these components when the Hard Disk Drives are behind an HP Smart
Array H220/H222 controller is only supported offline
HP SUM does not reboot a node after using Localhost Guided Update on Red Hat hosts
Suggested Action: Reboot the server manually after shutting down HP SUM.
Aborting deployment and restarting deployment on iPDU nodes causes HP SUM to unexpectedly quit
Suggested Action: If you abort an iPDU update, shut down HP SUM and relaunch it before you attempt
to deploy the updates again.
22 Issues and suggested actions