HP ProLiant DL360p Gen8 Server Maintenance and Service Guide

Table Of Contents
Removal and replacement procedures 44
2.
Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Extend the server from the rack (on page 26).
4. Remove the access panel ("Access panel" on page 30).
5. Remove the fan blanks.
To replace the component, reverse the removal procedure.
Flash-backed write cache procedures
Two types of procedures are provided for the FBWC option:
Removal and replacement of failed components:
o Removing the cache module ("Cache module" on page 44)
o Removing the capacitor pack ("FBWC capacitor pack" on page 45)
Recovery of cached data from a failed server ("Recovering data from the flash-backed write cache" on
page 46)
CAUTION: Do not detach the cable that connects the battery pack or capacitor pack to the cache
module. Detaching the cable causes all data in the cache module to be lost.
Cache module
To remove the component:
1. Power down the server (on page 25).
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.