HP Smart Update Manager 5.3.5 Release Notes (Ed. 3)

4. If you want to terminate this process before reaching the end of the list, press q or Q and the Enter
key.
NOTE: You might need to do more configuration after you enable a service.
If you disable a service, you might lose the connection to the switch.
When you enable SSL, make sure that the date and time settings on the switch and the workstation
making the SSL connection match. You might need to create a new certificate to ensure a secure
connection to the switch. Use the following settings:
TelnetEnabled (True / False) [True ]
SSHEnabled (True / False) [False] True
GUIMgmtEnabled (True / False) [True ]
SSLEnabled (True / False) [False] True
EmbeddedGUIEnabled (True / False) [True ]
SNMPEnabled (True / False) [True ]
NTPEnabled (True / False) [False]
CIMEnabled (True / False) [False]
FTPEnabled (True / False) [True ]
MgmtServerEnabled (True / False) [True ]
Do you want to save and activate this services setup? (y/n): [n] y
When HP SUM attempts to discover a switch that is a part of Virtual Fabric Configuration,
HP SUM might unexpectedly close
HP SUM does not support discovering switches that are in a Virtual Fabric Configuration.
Suggested action: Do not add a switches that are in a Virtual Fabric Configuration as a target.
HP SUM might display the message Qt : Untested Windows version 6.2 detected!
When starting HP SUM in Windows Server 2012, you might see the message Qt: Untested
Windows version 6.2 detected!
Suggested action: This issue occurs because HP SUM detects the version of Windows incorrectly. You
can disregard the warning and continue with the installation.
HP SUM might select NIC firmware components when you use the f:software parameter
in CLI mode
If you run HP SUM in CLI mode, and use the f:software command, HP SUM might select updated
NIC firmware components as components to install.
Suggested action: Open HP sum in GUI mode and go to the Component Selection or Bundle selection
screen. If firmware components have been selected, de-select the firmware components before beginning
the update.
When using the HP SUM CLI, the command /f:software lists firmware components
In CLI mode, if you use the command /f:software, HP SUM will select software and firmware for
Smart Array controller, hard disc drives, power management controllers, and some NIC components.
Suggested action: Use HP SUM in GUI mode.
HP SUM for Windows might not update the Intel IXN driver for Windows 2012 in Hyper-V
When attempting to update the Intel IXN NIC, HP SUM shows the driver as already up to date.
Suggested action: Update the NIC as a standalone component.
Issues and suggested actions 17