HP ProLiant Storage Server SAN Connection and Management application notes Part number: 5697–6495 Fourth edition: September 2007
Legal and notice information © Copyright 2007 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. Microsoft® and Windows® are U.S.
About this document These application notes describe methods and procedures for connecting HP storage servers to a storage area network (SAN) based on your type of Fibre Channel array. For the latest version of this document, go to http://www.hp.com/support/manuals. Under the storage section, click Disk Storage Systems, then NAS/Storage Servers, and select a SAN-capable storage server model (for example, the DL380 G5). Links to the most current documentation available are displayed on the page.
Table 1 MSA 1000/1500 driver versions for supported FC HBAs MSA 1000/1500 Driver SCSIPORT Driver StorPort Firmware Boot BIOS A7387A (LP1050DC) A7388A (LP1050) 5–5.30a2 5–1.20a7 1.91a5 1.71a0 (5.02a1) FC 1142SR (QLE2460) FC1242SR (QLE2464) 9.1.3.11 9.1.3.16 N/A 1.16 (1.41) FC 1143 (QLA2460) FC1243 (QLA2462) 9.1.3.11 9.1.3.16 N/A 1.16 (1.41) FC 2142SR (LPe1150) FC2242SR (LPe11002) 5–5.30a2 5–1.20a7 2.50a6 1.71a0 (5.02a1) FC 2143 (LP1150) FC2243 (LP11002) 5–5.30a2 5–1.20a7 2.
HP SecurePath version: 4.0c SP2–1 HP MPIO version: HP MPIO Basic DSM (Device Specific Module) for Windows for MSA 1000/1500 Active/Passive Disk Arrays version 1.40 HP MPIO Full Featured DSM for MSA (Active/Active) Disk Arrays version 1.00.01 If you have a NAS system unit configured for high availability, install Multipath Input/Output (MPIO) software. Currently, two software MPIOs are supported for these storage arrays: HP StorageWorks SecurePath and HP MPIO DSM.
EVA3000 EVA5000 Driver SCSIPORT Driver StorPort Firmware Boot BIOS FC2142SR (LPe1150) FC2242SR (LPe11002) 5–5.30a2 5–1.20a7 2.50a6 1.71a0 (5.02a1) FC2143 (LP1150) FC2243 (LP11002) 5–5.30a2 5–1.20a7 2.10a10 1.71a0 (5.02a1) FCA2214 (QLA2340) FCA2214DC (QLA2342) 9.1.3.11 9.1.3.16 N/A 1.45 FCA2404 (LP9802) FCA2404DC (LP9802DC) 5–5.30a2 5–1.20a7 1.91a5 1.71a0 (5.02a1) LP10000 LP10000DC 5–5.30a2 5–1.20a7 1.91a5 1.71a0 (5.02a1) FCA 2408343073–B21 5–5.30a2 5–1.20a7 1.91a5 1.
Driver SCSIPORT Driver StorPort Firmware Boot BIOS FC1143 (QLA2460) FC1243 (QLA2462) 9.1.3.11 9.1.3.16 N/A 1.16 (1.41) FC2142SR (LPe1150) FC2242SR (LPe11002) 5–5.30a2 5–1.20a7 2.50a6 1.71a0 (5.02a1) FCA 2408 343073-B21 (2Gbps, 32/64-bit PCI-X) 5–5.30a2 5–1.20a7 1.91a5 1.71a0 EVA 4000/6000/ 8000 If you update the HBA driver version, firmware, or boot BIOS, be sure to reboot the system after the update before you continue.
2. Verify that the firmware revision for the EVA array is installed. EVA 3000/5000 firmware revision: 3.100 or 4.007 EVA 4000/6000/8000 firmware revision: 6.100 Contact HP Service and Support to obtain the latest firmware version for your storage array. If you update the firmware, be sure to reboot the system after the update before you continue. 3. Install multipath software (SecurePath or HP MPIO DSM). HP SecurePath version: 4.
Table 4 Disk Array XP 10000 and XP 12000 driver versions for supported FC HBAs XP10000 XP12000 Driver SCSIPORT Driver StorPort Firmware BootBIOS A7387A (LP1050DC) A7388A (LP1050) 9.1.0.13 9.1.0.18 N/A 1.45 FC1142SR (QLE2460) FC1242SR (QLE2462) 9.1.3.11 9.1.3.16 N/A 1.16 (1.41) FC1143 (QLA2460) FC1243 (QLA2462) 9.1.3.11 9.1.3.16 N/A 1.16 (1.41) FC2142SR (LPe1150) FC2242SR (LPe11002) 5–5.30a2 5–1.20a7 2.50a6 1.71a0 (5.02a1) FC2143 (LP1150) FC2243 (LP11002) 5–5.30a2 5–1.20a7 2.
XP128 XP1024 Driver SCSIPORT Driver StorPort Firmware BootBIOS FC2143 (LP1150) FC2243 (LP11002) 5–5.30a2 5–1.20a7 2.10a 10 1.71a0 (5.02a1) FCA2214 (QLA2340) FCA2214DC (QLA2342) 9.1.3.11 9.1.3.16 N/A 1.45 FCA2404 (LP9802) FCA2404DC (LP9802DC) 5–5.20a10 5–1.11x1 1.91a1 1.71a3 LP10000 LP10000DC 5–5.30a2 5–120a7 1.91a5 1.71a0 (5.02a1) FCA 2408 34073–B21 5–5.30a2 5–1.20a7 1.91a5 1.71a0 (5.
5. Install SecurePath Manager (optional). If you use SecurePath, and want to install SecurePath Manager, see “Secure Path Manager (optional)” on page 11. SecurePath Manager (optional) SecurePath Manager provides web-based management capability for cross-platform SecurePath configurations. This application displays a graphical representation of multiple path configurations, indicating the status of a user-defined set of hosts, storage systems, and paths.
Figure 1 Expanding a LUN (Smart Array only) NOTE: The Expand Array task is listed only if there is an unassigned physical drive on the controller. The unassigned drive must also have a capacity no less than that of a drive in an existing array. If these conditions are not fulfilled, install at least one suitable drive on the controller, and then click Refresh. There are two scenarios to adding storage for array expansion (Smart Array storage only): • Add an unassigned physical disk to the array.
Expanding storage for Enterprise Virtual Arrays (single node environment) The act of presenting a virtual disk makes it available for use by a host. You can present a virtual disk to a host during or after virtual disk creation. The virtual disk must be completely created before the host presentation can occur. If you choose host presentation during virtual disk creation, the management agent cannot complete any other task until that virtual disk is created and presented.