HP ProLiant Storage Server SAN Connection and Management Application Notes (5697-6495, September 2007)

Table 1 MSA 1000/1500 driver versions for supported FC HBAs
MSA 1000/1500
Driver SCSIPORT Driver StorPort Firmware Boot BIOS
A7387A
(LP1050DC)
A7388A
(LP1050)
5–5.30a2 5–1.20a7 1.91a5 1.71a0 (5.02a1)
FC 1142SR
(QLE2460)
FC1242SR
(QLE2464)
9.1.3.11 9.1.3.16
N/A
1.16 (1. 41)
FC 1143
(QLA2460)
FC1243
(QLA2462)
9.1.3.11 9.1.3.16
N/A
1.16 (1. 41)
FC 2142SR
(LPe1150)
FC2242SR
(LPe11002)
5–5.30a2 5–1.20a7 2.50a6 1.71a0 (5.02a1)
FC 2143
(LP1150)
FC2243
(LP11002)
5–5.30a2 5–1.20a7 2.10a10 1.71a0 (5.02a1)
FCA 2214
(QLA2340)
FCA2214DC
(QLA2342 )
9. 1.3. 1
1
9. 1.3. 1
6
N/A
1. 45
FCA 2404
(LP9802)
FCA2404DC
(LP9802DC)
5–5.30a2 5–1.20a7 1.91a5 1.71a0 (5.02a1)
LP 10000
LP10000DC
5–520a10
5–1.11x1
1.91a1 1.70a3
FCA
2408
343073–B21
5–5.30a2 5–1.20a7 1.91a5 1.71a0 (5.02a1)
If yo
u update the HBA driver version, rmware, or boot BIOS, be sure to reboot the system af ter the
update before you continue.
Contact HP Ser vice and Support:
•Toge
t the latest driver version, rmware, or boot BIOS for HBA driv ers
If your HBA PCI cards are not listed in Table 1
2. Verify that the rmware revision for the MSA array is installed.
MSA1
000/1500 Active/Passive
rm
ware revision:
5.20
MSA1000/1500 Active/Active
rmware revision:
7.0 0
The rmware can be downloaded without cost from http:/ /www.h p.com/go/msa. Otherwise,
contact HP Ser vice and Suppor t to obtain the latest rmwareforyourstoragearray.
If you update the rmware, be sure to reboot the system af ter the update before you continue.
3. Install multipath software (SecurePath or HP MPIO DSM).
4