HP StorageWorks All-in-One Storage Manager user guide (452695-004, November 2008)

Storage tab—Displays the user-defined application's storage space, including allocated space,
used space, free space, and the following storage allocation details:
Table 21 Storage tab: User-defined application properties
ValueProperty
Path to the file directory on the application server where the user-defined
application data is saved by the user-defined application. The file
directory is located on the volume created on the iSCSI LUN that was
exported by ASM to the application server.
Application Path
Communication protocol used to transfer data between the server that
hosts the user-defined application and your HP Storage Server.
Protocol
Name of server that hosts the user-defined application.Application Server Host Name
Name of the volume on the application server to which the user-defined
application saves its data. The volume resides on the iSCSI LUN (logical
disk) exported by ASM to the application server.
Application Server Volume -
Name
Status of the volume on the application server where the user-defined
application data is stored.
Application Server Volume -
Status
Indicates if user-defined application storage is configured with exclusive
storage. See Table 5 on page 23 for more information.
Application Server Volume -
Exclusive Storage
The RAID level to which the user-defined application storage is
configured. See Customizing RAID levels on page 24 for more
information.
Application Server Volume - RAID
Level
The RAID stripe size to which the user-defined application storage is
configured. See Table 5 on page 23 for more information.
Application Server Volume - RAID
Stripe Size
Speeds up reads when enabled. This setting is determined by the
storage array, not ASM.
Application Server Volume - Read
Cache
Speeds up writes when enabled. This setting is determined by the
storage array, not ASM.
Application Server Volume -
Write Cache
The number of hot spares with which the database component storage
is configured. See Table 5 on page 23 for more information.
Application Server Volume -
Number of Hot Spares
Path the application server volume is mounted on. The volume is built
on the iSCSI LUN exported by ASM to the application server.
Application Server Volume -
Mount Paths
Warning Threshold tab—Allows you to change the percent full warning threshold value for the
user-defined application. See Setting a percent full warning threshold on page 26 for more
information.
Snapshots tab — Allows you to schedule snapshots of the user-defined application. For more
information, see “Scheduling and running snapshots” on page 33.
Backup tab — Allows you to schedule backups of the user-defined application. See
Scheduling backups” on page 36 for more information.
Replication tab — Allows you to configure data replication of the user-defined application. See
Running replication” on page 40 for more information.
All-in-One Storage Manager 57