HP Smart Update Manager 5.3 User Guide
2. Select IP Address Range, Port Address, or LDAP Scan for Remote Targets, and then click OK.
• IP Address–Enables you to search a range of IP addresses in IPv4 or IPv6 format. Enter
the required address range information, click Search, select the target, and then click
Add to List.
NOTE: HP SUM searches only c-class blocks of IP addresses, and a maximum of 255
targets. For example, you can search for IP address 192.168.1.1 through 192.168.1.255,
but HP SUM does not support searching IP addresses 192.168.1.1 through
192.168.3.255.
• Port Address–Enables you to search in a range of IP addresses and specific port address.
• LDAP Scan for Remote Targets–Enables you to search for targets using an LDAP query.
Adding a single target
1. Click Add Single Target.
2. Type the IP or DNS address of the target.
3. Select the type of target from the dropdown list (optional). If you leave this field as the default
setting, HP SUM detect the type of target during the discovery process. If you select the correct
target type, the discovery process is faster.
4. Type a brief description of the target (optional).
5. Enter the root or administrator username and password.
6. Click OK. This begins the discovery process of the target that is added.
Updating VMware firmware
The following must be true to update a VMware ESXi 5 target:
• The target must be on active on the network so HP SUM can detect the target.
• You are not attempting to run HP SUM on the VMware target. You cannot execute HP SUM
locally to update a VMware ESXi 5 target.
• You are executing HP SUM on a Windows host computer.
• The VMware server must be running hp-smx-provider.vib 5.0.0 or later. You can download
the bundle from the HP ESXi Offline Bundle website at http://h18000.www1.hp.com/products/
servers/software/vmware-esxi/offline_bundle.html.
Entering target credentials
You must enter the credentials (administrator user name and password) for all targets, including
the local host, if you are updating it.
1. In the Select Targets screen table, select one or more targets by clicking to highlight the rows.
2. Click Enter Credentials.
3. In the Enter Credentials for the Target(s) dialog box, select one or more targets. The credentials
you enter are applied to all selected targets. The Select All button selects all targets in the list.
4. Click Add Credentials.
5. In the Enter Credentials for Target dialog box:
a. Enter a user name and password with root or administrator rights.
b. Select what HP SUM should do if it detects an update already running.
6. Click OK to save and close the dialog box.
7. Click Done.
22 Using the HP SUM GUI