HP ProLiant Storage Server with Windows Storage Server 2003 R2 - Release Notes (5697-6072, September 2006)

System installation and recovery process
Issue:
After performing installation or recover y, the machine boots again to the System Installation and
Recovery me nu rather than the Windows logon screen
Description
If the
recovery DVD is left in the drive of an ML310 G3 storage server, the system
will boot again
from the DVD, even though the installation or recovery process
is
complete.
Workaround Remove the DVD and reboot the machine.
Issue:
After restoring the system with th e System Installation and Recovery DVD, the data drive may be
seen by Windowsasaforeigndisk
Description
If the
data drive was a dynamic disk prior to performing a system recovery, the
disk may be designated as a foreign disk by Windows after the recover y. This
issue is seen in the Disk Management MMC snap-in.
Workaround
Open the Disk Management snap-in. Right-click on the foreign disk a nd select
Import disk.
Issue:
NfsSvr logs an error in the event log
Description
On
systems with Windows Storage Ser ver 2003 R2, the event log may contain an
error stating that Server for NFS failed to initialize on a non-existent drive letter.
For example:
Event Type: ErrorEvent
Source: NfsSvr
Event Category: None
Event ID: 1066
Description: Server for NFS failed to initialize
on volume with drive letter F:
Workaround
This error does not affect the performance of NFS. The issue will be resolved in a
later HP ProLiant Storage Server release.
Documentation updates
This section describes issues related to docu m entation for the stora ge servers.
Docum
entation
updates
Issue:
Incorrect note about User Name Mapping component in Windows Storage Server 2003 R2
administration guide
Description
An incorrect note appears on the rst page of chapter 7 in the following March
2006 administration guides:
HP ProLiant DL100 G2 Storage Server administration guide, part number
569 7-55 8 7
HP ProLiant DL380 G4 Stora ge Ser ver administration guide, part number
569 7-5669
HP ProLiant DL585 Storage Server administration guide, p art number
5697-5592
HP ProLiant ML310G3Storage Server administration guide, part number
5697-5597
Thenotereads: After the Windows Storage Server R2 release,
the User Name Mapping component will no longer ship with
Microsoft Services for NFS.
W
orkaround
P
leaseignorethis note.