HP StorageWorks Clustered Gateway (software-only) 3.6.0 Windows Storage Server Edition Upgrade Guide (433702-002, January 2008)

Table Of Contents
Chapter 4: Non-Rolling Upgrades 20
2. Back up the cluster configuration on each server in group A as
described under “Back Up the Existing Cluster” on page 5.
3. Shut down the servers in group A.
4. Reinstall the operating system on the servers in group A.
5. If you will be adding third-party MPIO software to the cluster, install
it on each server in group A according to the product documentation.
6. On each server in group A, install a version of the HBA driver that is
supported by HP Clustered File System. (See the HP StorageWorks
Enterprise File Services Clustered Gateway QuickSpecs, available from the
C
lustered Gateway website, for a list of supported drivers.)
7. Reboot the servers in group A.
8. Run the HP mxcheck utility on the servers in group A. This utility
verifies that the servers configuration meets the requirements for
running HP Clustered File System.
To run mxcheck, insert the HP Clustered File System CD into the CD
drive or go to the directory where you downloaded the product and
then double-click the file mxcheck.exe.
Output from the utility appears on the screen and is also written to the
Application Log section of the Event Viewer. We recommend that you
fix any problems identified by mxcheck before you install HP
Clustered File System.
9. On each server in group A, install HP Clustered File System 3.6.0.
Locate the file MxS_3.6.0.<xxxx>.msi on the product CD or in the
directory where you downloaded the software. Double-click on the
MxS_3.6.0.<xxxx>.msi file and run the Installation Wizard. To complete
the installation, reboot the servers when directed by the popup
message.
10. On each server in group A, install FS Option for Windows. Insert the
product CD into the CD drive or go to the location where you have
downloaded the software. Then double-click the file
MxFS_3.6.0.<xxxx>.msi and run the Installation Wizard.