HP StorageWorks X5500 Network Storage Gateway for Windows setup guide (AP809-96004, October 2009)

Chapter3:SettingUpHPStorageWorksClusteredFileSystem 19
15. Install Hardware Snapshot Software (Optional)
HardwaresnapshotsaresupportedonHewlettPackardStorageWorks
EnterpriseVirtualArray(EVA )storagearrays.Ifyouwillbeusingthis
feature,thefollowingsoftwaremustbeinstalledontheserversinthe
cluster.
HP EVA Storage Arrays
TotakehardwaresnapshotsorsnapclonesonHPStorageWorks
EnterpriseVirtualArray(EVA)storagearrays,asupported
versionofthe
HPStorageWorksScriptingSystemUtility(SSSU)mustbeinstalledonall
serversinthecluster.Also,asupportedversionofCommandViewEVA
softwaremustbeinstalledonyourManagementAppliance.Besurethat
yourversionsofSSSUandCommandViewEVAareconsistent.TheSSSU
utilitymustberenamed
to
%ProgramFiles%\HewlettPackard\SANworks\ElementManagerfor
StorageWorksHSV\Bridge\sssu.exe.Toobtainthissoftware,contact
yourHPrepresentative.
IfMicrosoftWindowsSP2isnotinstalledonyourservers,youwillalso
needtoinstallMicrosoftKnowledgeBaseHot fix899415.Thehotfixis
availableat:
http://support.microsoft.com/default.aspx?scid=kb;enus;899415
16. Configure the Cluster
Configuration Information
TheclusterisconfiguredfromtheHPManagementConsole.Youwillbe
askedforthefollowinginformation:
•TheIPaddressorhostnameofeachserverthatwillbeinthecluster.
•ThelocationofyourHPClusteredFileSystemlicensefile.
•Asecretnetworkkeythatprovidessecurityfornetwork
communications
amongtheclusterservers.
•Thefencingmethodthatyouwanttouse(eitherFibreChannelswitch
basedfencingorWebManagementbasedfencingviaserverreset/
shutdown).