HP StorageWorks X5500 Network Storage Gateway for Windows setup guide (AP809-96004, October 2009)

AppendixA:ConfiguretheClusterfromtheCommandLine 52
mx server start <node>
StartHPClusteredFileSystemonthespecified node.
mx config description <description>
TheclusternameordescriptionappearsonthetitlebaroftheHP
ManagementConsole.Thenameordescriptioncancontainupto80
characters.
mx config webfencing --ruser <user name> --vendor <vendor> --mixedvendor
yes|no --hostname <name>|--hostsuffix <suffix> |--ipdelta <delta>
[--type reset|shutdown] [--bladeslot <slot>] [--sharedlogin yes|no]
[--rpassword <password>]
Configurewebmanagementbasedfencing,inwhichHPClustered
FileSystemusesremotemanagementhardwareontheserverto
removeitsaccesstoPSFSfilesystems.iSCSIstoragemustusethis
fencingmethod.Whenconfiguringwebmanagementbasedfencing,
youwillneedtospecifyhowHPClusteredFileSystemshould
identifythe
RemoteManagementControllerassociatedwitheach
server.Useoneofthesemethods:
--hostname <host name>
SpecifythehostnamefortheRemoteManagementController
associatedwiththisserver.Youwillneedtousethismethodifyour
RemoteManagementControllersarefromdifferentvendors.
--hostsuffix <host suffix>
Specifythecommonsuffixtoappendtoeachservernameto
determinetheassociatedRemoteManagementControllername.For
example,ifyourservernamesareserver1andserver2andtheir
RemoteManagementControllersareserver1iLOandserver2iLO,
enteriLOasthesuffix.
--ipdelta <ip delta>
SpecifythedeltatoaddtoeachserversIPaddresstodeterminetheIP
addressesoftheassociatedRemoteManagementControllers.For
example,ifyourserversare1.255.200.12and1.255.200.15andtheir
RemoteManagementControllersare1.255.201.112and1.255.201.115,
enter0.0.1.100asthedelta.