Removal and replacement procedures 47
4.
Attach the ground (earthed) wire to the ground screw and washer and tighten to 1.47 N m (13 lb-in) of
torque. The ground wire must be connected before the positive or negative lead wires.
5. Attach the power ring tongues to the terminal block, following the polarity label below the terminal