HP ProLiant Gen8 Troubleshooting Guide Volume II: Error Messages
HP Smart Array errors 114
• “EJECTED”
• “ERASING”
• “UNKNOWN”
Message identifiers 24600-24624
Message Id: 24600
Severity: Error
Log message: Logical drive <logical drive number> of array controller <controller
name / slot information> has encountered a status change from:
Status: <previous status>
to
Status: <current status>
<previous status> and <current status> values:
• “OK”
• “FAILED”
• “NOT CONFIGURED”
• “INTERIM RECOVERY MODE”
• “READY FOR RECOVERY”
• “RECOVERING”
• “WRONG PHYSICAL DRIVE REPLACED”
• “PHYSICAL DRIVE NOT PROPERLY CONNECTED”
• “HARDWARE IS OVERHEATING”
• “HARDWARE HAS OVERHEATED”
• “EXPANDING”
• “NOT YET AVAILABLE”
• “QUEUED FOR EXPANSION”
• “DISABLED DUE TO SCSI ID CONFLICT”
• “EJECTED”
• “ERASING”
• “UNKNOWN”
Message Id: 24601
Severity: Informational
Log message: Logical drive <logical drive number> configured on array controller
<controller name / slot information> is in a failed state but has had one or more
drive replacements and is now ready to change to a status of "OK". However, this
status change will not occur until the logical drive is re-enabled. Please
re-enable the logical drive either via the HP Array Configuration Utility or by
rebooting the system.