HP ProLiant Gen8 Troubleshooting Guide Volume II: Error Messages

HP Smart Array errors 129
Log message: A SAS link error has been detected between I/O module <module number
1> of box <box number 1> and I/O module <module number 2> of box <box number 2>.
These boxes are connected to port <port number> of array controller <controller
name / slot information>. Please check this data path and the associated hardware.
Message Id: 24697
Severity: Warning
Log message: A SAS link error has been detected in bay <bay number> of box <box
number> which is connected to port <port number> of array controller <controller
name / slot information>. Please check this data path and the associated hardware.
Message Id: 24698
Severity: Warning
Log message: A SAS link error has been detected between array controller <controller
name / slot information> and the switch expander connected to port <port number>
of this controller. Please check this data path and the associated hardware.
Message Id: 24699
Severity: Warning
Log message: A SAS link error has been detected between a switch expander and I/O
module <module number> of box <box number>. This hardware is connected to port
<port number> of controller <controller name / slot information>. Please check
this data path and the associated hardware.
Message identifiers 24700-24724
Message Id: 24700
Severity: Informational
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> has reported that a <drive type> physical hard drive in bay
<bay number> was <inserted / removed>.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message Id: 24701
Severity: Error
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> has reported that fan number <fan number> has failed. The
external Smart Array controller may attempt to shut down power and/or spin down
the installed disk drive(s).
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message Id: 24702
Severity: Informational
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> has reported that fan number <fan number> is reporting a
degraded condition.