HP ProLiant Gen8 Troubleshooting Guide Volume II: Error Messages

HP Smart Array errors 138
Severity: Warning
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> has reported that its cache batteries have failed.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message Id: 24724
Severity: Informational
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> has reported that an error log update has occurred for the
physical drive with BMIC device index <device index>.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message identifiers 24725-24749
Message Id: 24725
Severity: Informational
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> has reported that the consistency initialization pass has
completed for logical drive <logical drive number>.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message Id: 24726
Severity: Warning
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> has reported an uncorrectable read error during surface
analysis operations for logical drive <logical drive number>. A media error was
encountered that is not correctable due to media errors on other physical drive(s)
belonging to this logical volume. The uncorrectable media defects are between
logical block address <lba number 1> and logical block address <lba number 2>.
The host will be unable to read some blocks between this address range until the
blocks are overwritten. Capacity expansion operations must be avoided while the
blocks are unreadable.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message Id: 24727
Severity: Informational
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> has reported that the surface analysis uncorrectable read error
condition for logical drive <logical drive number> has ended. The previously
reported media defects have been overwritten. Capacity expansion operations may
now be conducted.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message Id: 24728