HP ProLiant Gen8 Troubleshooting Guide Volume II: Error Messages

HP Smart Array errors 147
Severity: Informational
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> has reported that fan number <fan number> located on fan module
<fan module number> is reporting a degraded condition.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message Id: 24772
Severity: Informational
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> has reported that fan number <fan number> located on fan module
<fan module number> is now operational.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message Id: 24773
Severity: Informational
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis number> has reported that a tape drive has been <inserted / removed>.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message Id: 24774
Severity: Informational
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> is reporting <link up / down> for PHY number <PHY number>.
This PHY link status change has occurred on port <port number> of the external
array controller.
The external Smart Array controller reporting this event is attached to the host
side Smart Array controller <controller name / slot information>.
Message identifiers 24775-24799
Message Id: 24775
Severity: Warning
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> is reporting that the <drive type> physical hard drive located
in bay <bay number> is offline. The offline reason received from the HP Smart
Array firmware is: <firmware error code>.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
<firmware error code> values:
TOO_SMALL_IN_LOAD_CONFIG - Replacement drive is too small for configured
volume(s).
ERROR_ERASING_RIS - Could not write to reserved configuration sectors after
multiple retries.