HP ProLiant Gen8 Troubleshooting Guide Volume II: Error Messages

HP Smart Array errors 153
is approaching the maximum usage limit for writes (wear out). The drive should
be replaced as soon as possible.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message Id=24791
Severity: Error
Log message: Array controller <controller name / slot information> has reported that
its internal temperature has exceeded the preset limit of <temperature limit>°C.
The current temperature is <current temperature>°C as reported by sensor number
<sensor number>. The controller may attempt to shut down power and/or spin down
installed disk drives.
Message Id: 24792
Severity: Warning
Log message: Array controller <controller name / slot information> has reported that
its internal temperature is nearing the preset temperature limit of <temperature
limit>°C. The current temperature is <current temperature>°C as reported by
sensor number <sensor number>. The array controller may enact precautionary
measures to prevent data loss should the temperature reach the operating limit.
Message Id: 24793
Severity: Informational
Log message: Array controller <controller name / slot information> has reported that
a previously existing temperature condition on the controller from sensor <sensor
number> has been corrected. All of the temperature sensors are now reporting
acceptable temperature levels.
Message Id: 24794
Severity: Error
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis number> is indicating that sensor number <sensor number> has reported
that the internal temperature of <internal temperature>°C has exceeded the preset
temperature limit of <temperature limit>°C. The external Smart Array controller
may attempt to shut down power to and/or spin down installed disk drives.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message Id: 24795
Severity: Warning
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> is indicating that its internal temperature is nearing the
preset temperature limit of <temperature limit>°C. The current temperature is
<current temperature>°C as reported by sensor number <sensor number>. The
external Smart Array controller may enact precautionary measures to prevent data
loss should the temperature reach the operating limit.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message Id: 24796
Severity: Informational