HP ProLiant Gen8 Troubleshooting Guide Volume II: Error Messages

HP ProLiant server errors 25
Swapped Cables or Configuration Error Detected. An Unsupported Drive
Arrangement Was Attempted...
...SOLUTION: Power down system then move drives back to their original location.
Description: One or more physical drives were moved, causing a configuration that is not supported.
Action: Move all drives to their original locations, and then refer to the server documentation for supported
configurations.
Swapped cables or configuration error detected. The cables appear to be
interchanged...
...SOLUTION: Power down system then move the drives or cables back to their original location.
Description: ADU has detected a change in the cable configuration. One or more cables may be connected
to the incorrect bus or one or more drives have been moved to new locations.
Action:
1. Refer to the server documentation for supported configurations and cabling guidelines.
2. Restore to the original configuration.
Swapped cables or configuration error detected. The configuration information on
the attached drives...
...is not backward compatible with this controller’s firmware.
SOLUTION: Upgrade the firmware on this controller. If this doesn’t solve the problem then power down system then
move drives back to the original controller.
Description: The current firmware version on the controller cannot interpret the configuration information on
the connected drives.
Action: Update the controller to the latest firmware version.
or
If the problem persists, move the drives to the original controller.
Swapped Cables or Configuration Error Detected. The Maximum Logical Volume
Count X...
...was exceeded during logical volume addition. All logical volumes beyond X have been lost and cannot be
recovered.
SOLUTION: Identify the drives that contain the lost logical volumes. Move those drives to another controller where the
logical volumes can be recreated. NOTE! If a drive contains a valid logical volume and a lost logical volume, then do
not move that drive to another controller.
Description: More logical drives were created than are supported on this controller, causing lost logical drive
volumes.
Action: Identify the drives containing lost volumes, and then move them to another controller so the lost
volumes can be recreated.
CAUTION: Removing a drive that contains valid volume data causes all valid data to be lost.