HP ProLiant Gen8 Troubleshooting Guide Volume II: Error Messages

Microsoft Windows Event ID and SNMP traps 290
Supporting SNMP Trap Description: “Spare Status is now [cpqFcaSpareStatus] on bus
[cpqFcaSpareBusNumber].”
NT Event ID: 1148 (Hex)0xc435047c (cpqstmsg.dll)
Log Severity: Error (3)
Event Title: External Array Accelerator Status Change.
Log Message: The array accelerator board attached to the external controller in I/O slot %5 of array “%4”
has a new status of %6.
SNMP Trap: cpqFca2AccelStatusChange - 16017 in CPQFCA.MIB
Symptom: External Array Accelerator Board Status Change. This trap indicates that the agent has detected
a change in the status of an Array Accelerator Cache Board. The current status is represented by the variable
cpqFcaAccelStatus.
User Action: If the accelerator board status is permDisabled(5), you may need to replace the accelerator
board.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqSsChassisName
cpqSsChassisTime
cpqFcaAccelBoxIoSlot
cpqFcaAccelStatus
cpqFcaCntlrModel
cpqFcaAccelSerialNumber
cpqFcaAccelTotalMemory
cpqFcaAccelErrCode
Supporting SNMP Trap Description: “Status is now [cpqFcaAccelStatus].”
NT Event ID: 1149 (Hex)0xc435047d (cpqstmsg.dll)
Log Severity: Error (3)
Event Title: External Array Accelerator Bad Data.
Log Message: The array accelerator board attached to the external controller in I/O slot %5 of array “%4”
is reporting that it contains bad cached data.
SNMP Trap: cpqFca2AccelBadDataTrap - 16018 in CPQFCA.MIB
Symptom: External Array Accelerator Board Bad Data. This trap indicates that the agent has detected an
Array Accelerator Cache Board that has lost battery power. If data was being stored in the accelerator
memory when the system lost power, that data has been lost.
User Action: Verify that no data has been lost.