HP ProLiant Gen8 Troubleshooting Guide Volume II: Error Messages

Microsoft Windows Event ID and SNMP traps 311
cpqFcTapeLibraryScsiBus
cpqFcTapeLibraryScsiTarget
cpqFcTapeLibraryScsiLun
cpqFcTapeLibraryModel
cpqFcTapeLibraryFWRev
cpqFcTapeLibrarySerialNumber
cpqFcTapeLibraryLocation
cpqFcTapeLibraryDoorStatus
Supporting SNMP Trap Description: “The door is [cpqFcTapeLibraryDoorStatus] for tape library.”
NT Event ID: 1199 (Hex)0x843504af (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: Drive Array Controller Status Change.
Log Message: The Drive Array Controller in %7 has a new status of %5.
SNMP Trap: cpqDa6CntlrStatusChange - 3033 in CPQIDA.MIB
Symptom: Controller Status Change. This trap indicates that the agent has detected a change in the status of
a drive array controller. The variable cpqDaCntlrBoardStatus indicates the current controller status.
User Action: If the board status is generalFailure(3), you may need to replace the controller. If the board
status is cableProblem(4), check the cable connections between the controller and the storage system.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqDaCntlrHwLocation
cpqDaCntlrIndex
cpqDaCntlrBoardStatus
cpqDaCntlrModel
cpqDaCntlrSerialNumber
cpqDaCntlrFWRev
cpqDaAccelTotalMemory
Supporting SNMP Trap Description: “Status is now [cpqDaCntlrBoardStatus].”
Event Identifiers 1200-1294
NT Event ID: 1200 (Hex)0x843504b0 (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: Drive Array Logical Drive Status Change.
Log Message: Logical drive number %5 on the array controller in %4 has a new status of %2.
SNMP Trap: cpqDa6LogDrvStatusChange - 3034 in CPQIDA.MIB