HP ProLiant Gen8 Troubleshooting Guide Volume II: Error Messages
Microsoft Windows Event ID and SNMP traps 321
• sysName
• cpqHoTrapFlags
• cpqDaCntlrHwLocation
• cpqDaPhyDrvCntlrIndex
• cpqDaPhyDrvIndex
• cpqDaPhyDrvLocationString
• cpqDaPhyDrvType
• cpqDaPhyDrvModel
• cpqDaPhyDrvFWRev
• cpqDaPhyDrvSerialNum
• cpqDaPhyDrvFailureCode
• cpqDaPhyDrvStatus
• cpqDaPhyDrvBusNumber
Supporting SNMP Trap Description: “Physical Drive Status is now [cpqDaPhyDrvStatus].”
NT Event ID: 1217 (Hex)0x843504c1 (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: Drive Array Spare Drive Status Change.
Log Message: The spare drive in %4, %5 has a new status of %2.
SNMP Trap: cpqDa7SpareStatusChange - 3047 in CPQIDA.MIB
Symptom: Spare Drive Status Change. This trap indicates that the agent has detected a change in the status
of a drive array spare drive. The variable cpqDaSpareStatus indicates the current spare drive status.
User Action: If the spare drive status is failed, replace the drive.
Supporting SNMP Trap Data:
• sysName
• cpqHoTrapFlags
• cpqDaCntlrHwLocation
• cpqDaSpareCntlrIndex
• cpqDaSparePhyDrvIndex
• cpqDaSpareStatus
• cpqDaSpareLocationString
• cpqDaSpareDrvBusNumber
Supporting SNMP Trap Description: “Spare Status is now [cpqDaSpareStatus].”
NT Event ID: 1218 (Hex)0x843504c2 (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: Storage System Fan Status Change.
Log Message: The %6 %7 storage system connected to %5 of the controller in%4 has a new status of %2.