HP ProLiant Gen8 Troubleshooting Guide Volume II: Error Messages

Microsoft Windows Event ID and SNMP traps 341
cpqHeFltTolPowerSupplyChassis
cpqHeFltTolPowerSupplyBay
cpqHeFltTolPowerSupplyStatus
cpqHeFltTolPowerSupplyModel
cpqHeFltTolPowerSupplySerialNumber
cpqHeFltTolPowerSupplyAutoRev
cpqHeFltTolPowerSupplyFirmwareRev
cpqHeFltTolPowerSupplySparePartNum
cpqSiServerSystemId
Supporting SNMP Trap Description: “The Power Supply AC power loss in [sysName], Bay
[cpqHeFltTolPowerSupplyBay], Status [cpqHeFltTolPowerSupplyStatus], Model
[cpqHeFltTolPowerSupplyModel], Serial Num [cpqHeFltTolPowerSupplySerialNumber], Firmware
[cpqHeFltTolPowerSupplyFirmwareRev].”
NT Event ID: 1072 (Hex)0x84350430 (cpqsvmsg.dll)
Log Severity: Warning (2)
Log Message: The frequency of memory errors is high enough such that tracking of correctable memory
errors has been temporarily disabled.
SNMP Trap: cpqHe3CorrectableMemoryLogDisabled - 6016 in CPQHLTH.MIB
Symptom: Correctable memory error tracking disabled. The frequency of errors is so high that the error
tracking logic has been temporarily disabled. The cpqHeCorrMemLogStatus variable indicated the current
tracking status.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqHeCorrMemLogStatus
Supporting SNMP Trap Description: “Too many memory errors - tracking now disabled.”
NT Event ID: 1082 (Hex)0xc435043a (cpqsvmsg.dll)
Log Severity: Error (3)
Log Message: A Thermal Temperature Condition has been set to failed. The system will be shut down due to
this thermal condition.
SNMP Trap: cpqHe3ThermalTempFailed - 6017 in CPQHLTH.MIB
Symptom: The temperature status has been set to failed. The system is shut down due to this thermal
condition.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
Supporting SNMP Trap Description: “System will be shut down due to this thermal condition.”
NT Event ID: 1083 (Hex)0x8435043b (cpqsvmsg.dll)