HP ProLiant Gen8 Troubleshooting Guide Volume II: Error Messages

Microsoft Windows Event ID and SNMP traps 352
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqHeFltTolPowerSupplyChassis
cpqHeFltTolPowerSupplyBay
Supporting SNMP Trap Description: “The Power Supply Inserted on Chassis
[cpqHeFltTolPowerSupplyChassis], Bay [cpqHeFltTolPowerSupplyBay].”
NT Event ID: 1128 (Hex)0x84350468 (cpqsvmsg.dll)
Log Severity: Warning (2)
Log Message: Fault Tolerant Power Supply Removed. A hot-plug fault tolerant power supply has been
removed from the system.
SNMP Trap: cpqHe3FltTolPowerSupplyRemoved - 6034 in CPQHLTH.MIB
Symptom: A Fault Tolerant Power Supply has been removed from the specified chassis and bay location.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqHeFltTolPowerSupplyChassis
cpqHeFltTolPowerSupplyBay
Supporting SNMP Trap Description: “The Power Supply Removed on Chassis
[cpqHeFltTolPowerSupplyChassis], Bay [cpqHeFltTolPowerSupplyBay].”
NT Event ID: 1129 (Hex)0x84350469 (cpqsvmsg.dll)
Log Severity: Warning (2)
Log Message: The Fan Sub-system is in a degraded state. Replace the fan.
SNMP Trap: cpqHe3FltTolFanDegraded - 6035 in CPQHLTH.MIB
Symptom: The Fault Tolerant Fan condition has been set to degraded for the specified chassis and fan.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqHeFltTolFanChassis
cpqHeFltTolFanIndex
Supporting SNMP Trap Description: “The Fan Degraded on Chassis [cpqHeFltTolFanChassis], Fan
[cpqHeFltTolFanIndex].”
NT Event ID: 1130 (Hex)0xc435046a (cpqsvmsg.dll)
Log Severity: Error (3)
Log Message: The Fan Sub-system is in a failed state. Replace the fan.
SNMP Trap: cpqHe3FltTolFanFailed - 6036 in CPQHLTH.MIB