HP ProLiant Gen8 Troubleshooting Guide Volume II: Error Messages

Microsoft Windows Event ID and SNMP traps 356
cpqHePwrConvChassis
cpqHePwrConvSlot
cpqHePwrConvSocket
Supporting SNMP Trap Description: “The Power Converter Failed on Chassis [cpqHePwrConvChassis], Slot
[cpqHePwrConvSlot], Socket [cpqHePwrConvSocket].”
NT Event ID: 1139 (Hex)0x84350473 (cpqsvmsg.dll)
Log Severity: Warning (2)
Log Message: The DC-DC power converter is in a failed state. Replace System Information Agent: Health: The
DC-DC Power Converter sub-system has lost redundancy. Replace any failed or degraded power converters.
SNMP Trap: cpqHe3PowerConverterRedundancyLost - 6045 in CPQHLTH.MIB
Symptom: The DC-DC Power Converters have lost redundancy for the specified chassis.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqHePwrConvChassis
Supporting SNMP Trap Description: “The Power Converters are no longer redundant on Chassis
[cpqHePwrConvChassis].”
NT Event ID: 1140 (Hex)0x84350474 (cpqsvmsg.dll)
Log Severity: Warning (2)
Log Message: Hot Plug PCI Board Removed. A hot plug PCI adapter has been removed from the system.
SNMP Trap: cpqSiHotPlugSlotBoardRemoved - 2008 in CPQSINFO.MIB
Symptom: Hot Plug Slot Board Removed. A Hot Plug Slot Board has been removed from the specified chassis
and slot.
User Action: None.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqSiHotPlugSlotChassis
cpqSiHotPlugSlotIndex
Supporting SNMP Trap Description: “Hot Plug Slot Board Removed from Chassis [cpqSiHotPlugSlotChassis],
Slot [cpqSiHotPlugSlotIndex].”
NT Event ID: 1141 (Hex)0x44350475 (cpqsvmsg.dll)
Log Severity: Information (1)
Log Message: Hot Plug PCI Board Inserted. A hot plug PCI adapter has been inserted into the system.
SNMP Trap: cpqSiHotPlugSlotBoardInserted - 2009 in CPQSINFO.MIB
Symptom: Hot Plug Slot Board Inserted. A Hot Plug Slot Board has been inserted into the specified chassis
and slot.