HP ProLiant Gen8 Troubleshooting Guide Volume II: Error Messages
Microsoft Windows Event ID and SNMP traps 368
• sysName
• cpqHoTrapFlags
• cpqRackName
• cpqRackUid
• cpqRackPowerSupplyEnclosureName
• cpqRackPowerSupplyPosition
• cpqRackPowerSupplyFWRev
• cpqRackPowerSupplyInputLineStatus
• cpqRackPowerSupplySparePartNumber
• cpqRackCommonEnclosureSerialNum
• cpqRackCommonEnclosureTrapSequenceNum
Supporting SNMP Trap Description: “The rack power supply detected an input line voltage problem in power
supply [cpqRackPowerSupplyPosition], enclosure [cpqRackPowerSupplyEnclosureName], rack
[cpqRackName].”
NT Event ID: 1162 (Hex)0x8435048a (cpqsvmsg.dll)
Log Severity: Warning (2)
Event Title: Rack Power Subsystem Overload
Log Message: The rack power subsystem overload condition.
SNMP Trap: cpqRackPowerSubsystemOverloadCondition - 22020 in CPQRACK.MIB
Symptom: The rack power subsystem overload condition.
User Action: Replace any failed power supplies as soon as possible to return the system to a redundant state.
Supporting SNMP Trap Data:
• sysName
• cpqHoTrapFlags
• cpqRackName
• cpqRackUid
• cpqRackPowerEnclosureName
• cpqRackCommonEnclosureSparePartNumber
• cpqRackCommonEnclosureSerialNum
• cpqRackCommonEnclosureTrapSequenceNum
Supporting SNMP Trap Description: “The power subsystem in enclosure [cpqRackPowerEnclosureName] in
rack [cpqRackName] is in an overload condition.”
NT Event ID: 1163 (Hex)0xc435048b (cpqsvmsg.dll)
Log Severity: Error (3)
Event Title: Server Power Shedding Shutdown
Log Message: Server shutdown due to power shedding.