HP ProLiant Gen8 Troubleshooting Guide Volume II: Error Messages

HP ProLiant server errors 45
Power Fault Detected in Hot-Plug PCI Slot X
Audible Beeps: 2 short
Possible Cause: A PCI-X hot-plug expansion slot was not powered up properly.
Action: Reboot the server.
Power Supply Solution Not Fully Redundant
Audible beeps: None
Possible cause: The minimum power supply requirement is installed, but a redundant power supply is missing
or failed.
Action: Do one of the following:
Install a power supply.
Replace failed power supplies to complete redundancy.
Processor X Unsupported Wattage.
Audible beeps: 1 long, 1 short
Possible cause: Processor not supported by current server.
Action:
CAUTION: Before removing or replacing any processors, be sure to follow the guidelines
provided in "Performing processor procedures in the troubleshooting process." Failure to follow
the recommended guidelines can cause damage to the system board, requiring replacement of
the system board.
See the server documentation for supported processors. If the processor is supported, remove the processor,
update the system to latest ROM, and then reinstall the processor.
Redundant ROM Detected - This system contains a valid backup system ROM.
Audible Beeps: None
Possible Cause: The system recognizes both the system ROM and redundant ROM as valid. This is not an
error.
Action: None
REDUNDANT ROM ERROR: Backup ROM Invalid. - ...
...run ROMPAQ to correct error condition.
Audible Beeps: None
Possible Cause: The backup system ROM is corrupted. The primary ROM is valid.
Action: Run ROMPaq Utility to flash the system so that the primary and backup ROMs are valid.
REDUNDANT ROM ERROR: Bootblock Invalid. - ...
...contact HP Representative.