HP ProLiant Gen8 Troubleshooting Guide Volume II: Error Messages

HP ProLiant server errors 57
Possible cause: Ultra-Low Voltage (1.25V) DIMMs are not supported.
Action: Install correct DIMMs.
237 - DIMM Configuration Error - Processor X, Channel Y
- Only 2 DIMMs can be installed on a channel containing Quad-Rank DIMM(s).
- System Halted!
Audible beeps: Repeating long beep
Possible cause: An incorrect number of DIMMs was detected on a channel containing Quad Rank DIMMs.
Action: Ensure the correct number of DIMMs are installed.
238 - DIMM Configuration Error - Processor X, Channel Y
- Quad Rank DIMMs must be installed in the first socket of any memory channel in which they are populated. - System
Halted!
Audible beeps: Repeating long beep
Possible cause: Quad Rank DIMMs are installed after SR or DR DIMMs.
Action: Ensure Quad Rank DIMMs are installed in the first socket of any memory channel.
239 - DIMM Configuration Error
- UDIMMs and RDIMMs are installed in the system. The system cannot have both types of DIMMs installed. - System
Halted!
Audible beeps: Repeating long beep
Possible cause: A DIMM configuration error exists with mismatched DIMMs.
Action: Ensure all DIMMs are of the same type.
240 - Unsupported Expansion Riser Board Detected One or more of the installed
expansion riser boards is not supported by this server.
Action: Replace the installed riser board with one supported by this server.
- System Halted!
Audible beeps: Constant long beep
Possible cause: The installed expansion riser board is not supported by this server.
Action: Replace the expansion riser board.
241 - Expansion Riser Board Detected in Incorrect Slot An expansion riser board is
installed in a riser slot in which it is not supported.
Action: Please move the expansion riser board to a slot in which it is supported. Refer to server documentation for
any requirements regarding the installation of expansion riser boards.
- System Halted!
Audible beeps: Constant long beep
Possible cause: The expansion riser board is installed in a non-supported slot.
Action: Move the expansion riser board to a supported slot.