HP ProLiant Gen8 Troubleshooting Guide Volume II: Error Messages

HP ProLiant server errors 62
605-Diskette Drive Type Error.
Audible Beeps: 2 short
Possible Cause: Mismatch in drive type occurred.
Action: Run the server setup utility to set the diskette drive type correctly.
611-Primary Floppy Port Address Assignment Conflict
Audible Beeps: 2 short
Possible Cause: A hardware conflict in the system is preventing the diskette drive from operating properly.
Action:
1. Run the server setup utility to configure the diskette drive port address and manually resolve the conflict.
2. Run Insight Diagnostics and replace failed components as indicated.
612-Secondary Floppy Port Address Assignment Conflict
Audible Beeps: 2 short
Possible Cause: A hardware conflict in the system is preventing the diskette drive from operating properly.
Action:
1. Run the server setup utility to configure the diskette drive port address and manually resolve the conflict.
2. Run Insight Diagnostics and replace failed components as indicated.
1100 Series
1151-Com Port 1 Address Assignment Conflict
Audible Beeps: 2 short
Possible Cause: Both external and internal serial ports are assigned to COM X.
Action: Run the server setup utility and correct the configuration.
1500 Series
1500: iLO 4 configuration is temporarily unavailable.
Possible cause: iLO is busy or unresponsive to the software that is running on the system.
Action: If the problem persists, perform the following:
1. Reboot the iLO processor.
2. Update the iLO firmware.
3. Reset the iLO NVRAM.
1501: iLO 4 Security Override Switch is set. iLO 4 security is DISABLED!
Possible cause: The iLO option ROM has detected the iLO security override switch is set to ON.