HP ProLiant Gen8 Troubleshooting Guide Volume II: Error Messages

HP ProLiant server errors 69
(no suitable backup found)
Audible Beeps: None
Possible Cause: The Bootstrap NVRAM on the specified Smart Array controller is corrupt or invalid.
Action:
1. Update the controller with the latest firmware version.
2. If the problem still exists, replace the controller.
1708-Slot X Drive Array Controller - Bootstrap NVRAM restored from backup. System
restart required
Audible Beeps: None
Possible Cause: The specified Smart Array controller Bootstrap NVRAM was restored in one of the following
ways:
It was detected as corrupt, and the backup copy was restored.
It was automatically updated because a newer version was available.
Action:
1. Reboot the server.
2. If the problem still exists, update the controller to the latest firmware version.
1709-Slot X Drive Array - One or more attached drives could not be authenticated as
a genuine HP drive...
...Smart Array will not control the LEDs to these drives. Please run ACU or ADU to learn which drives could not be
validated as genuine.
Audible beeps: None
Possible cause: One or more physical drives were attached to a non-array controller.
Action: To determine which drives cannot be validated as genuine, run ACU or ADU.
1710-Slot X Drive Array - Non-Array Controller Drives Detected Warning: possible
data loss may occur...
...Physical drive(s) detected which had been previously attached to a non-array controller. Any non-array data on
these drives will be lost unless they are removed. To save data, turn off system power immediately and remove the
drives.
Audible Beeps: None
Possible Cause: One or more physical drives were attached to a non-array controller.
Action: Power down the system, and then remove the drives.
1711-Slot X Drive Array - Stripe size too large for RAID 5/6 logical drive(s)
...This configuration is not recommended due to transfer buffer usage. Consider migrating to smaller stripe size via
Array Configuration Utility.