HP ProLiant Gen8 Troubleshooting Guide Volume II: Error Messages

HP ProLiant server errors 88
* Array Accelerator Battery Disconnected
* Array Accelerator Data Backup Failed
* Array Accelerator Backup Data Restore Failed
Audible Beeps: None
Possible Cause: Power was interrupted while data was in the array accelerator memory, or the array
accelerator batteries failed. Data in array accelerator has been lost.
Action:
1. Verify the integrity of the data stored on the drive. Power was not restored within enough time to save
the data.
2. Perform orderly system shutdowns to avoid leaving data in the array accelerator.
1794Slot X Drive Array Cache Module Battery Pack is Charging...
...Caching will be enabled once the Battery Pack has been charged. No action is required.
Audible beeps: None
Possible cause: The Cache Module Battery Pack is charging.
Action: No action is required.
1794-Slot X Drive Array - Cache Module Battery Pack/Super-Cap Removed or Not
Installed...
...Caching will be re-enabled when Battery Pack/Super-Cap is connected.
Audible beeps: None
Possible cause: The Cache Module Battery Pack or Super-Cap has been removed or is not installed.
Action: Install the battery pack or super-cap.
1794-Slot X Drive Array - Array Accelerator Battery is charging...
...The Array Accelerator will be enabled once the battery has been charged. No action is required.
Audible beeps: None
Possible cause: The Array Accelerator Battery is charging.
Action: No action is required.
1794-Slot X Drive Array - Array Accelerator Battery/Capacitor Removed...
...Array Accelerator battery/capacitor is removed or not installed. Accelerator will be reenabled when
battery/capacitor is connected.
Audible beeps: None
Possible cause: The Array Accelerator battery or capacitor pack has been removed or is not installed.
Action: Install the battery or capacitor pack.
1795-Slot X Drive Array - Write-Back Cache Configuration Error...
...Data does not correspond to this drive array. Caching is temporarily disabled.