HP ProLiant Gen8 Troubleshooting Guide Volume II: Error Messages

HP ProLiant server errors 89
Audible Beeps: None
Possible Cause: Power was interrupted while data was in the write-back cache, or the data stored in the
write-back cache does not correspond to this drive array.
Action: Match the write-back cache to the correct drive array, or run ACU to clear the data in the write-back
cache.
1795-Slot X Drive Array - Array Accelerator Configuration Error...
...Data does not correspond to this drive array. Array Accelerator is temporarily disabled.
Audible Beeps: None
Possible Cause: Power was interrupted while data was in the array accelerator memory, or the data stored
in the array accelerator does not correspond to this drive array.
Action: Match the array accelerator to the correct drive array, or run ACU to clear the data in the array
accelerator.
1796-Slot X Drive Array - Cache Module is Not Responding...
...Caching is temporarily disabled.
Audible Beeps: None
Possible Cause: Cache Module is defective or is missing. Depending on the array controller model, the cache
may be disabled or the controller might not be usable until this problem is corrected.
Action:
1. Reseat the cache module if the connector is loose.
2. If the problem persists, replace the cache module.
1796-Slot X Drive Array - Array Accelerator Not Responding...
...Array Accelerator is temporarily disabled.
Audible Beeps: None
Possible Cause: Array accelerator is defective or is missing. Depending on the array controller model, the
cache may be disabled or the controller might not be usable until this problem is corrected.
Action:
1. Reseat the array accelerator daughter board if the connector is loose.
2. If the problem persists, replace the board.
1797-Slot X Drive Array - Write-Back Cache Backup Previously Failed...
...Caching is disabled.
Audible beeps: None
Possible causes:
Super-cap could not provide the energy needed to complete the backup.
The data could not be copied to the Write-Back Cache.
The meta data stored in the Write-Back Cache could not be read or written.
Action: Replace the DIMM.