HP ProLiant Gen8 Troubleshooting Guide Volume II: Error Messages

HP ProLiant server errors 92
Audible Beeps: None
Possible Cause: The Cache Module Super-Cap is charging.
Action: No action is required.
1800-Slot X Drive Array - Array Accelerator Super-Cap is charging...
...The Array Accelerator Cache will be enabled once Super-Cap has been charged. No action is required.
Audible Beeps: None
Possible Cause: The Array Accelerator Super-Cap is charging.
Action: No action is required.
1801-Slot X Drive Array - Please install Cache Module Super-Cap...
...Caching will be enabled once Super-Cap is installed and charged.
Audible Beeps: None
Possible Cause: The Cache Module Super-Cap needs to be installed.
Action: Install the Cache Module Super-Cap.
1801-Slot X Drive Array - Please install Array Accelerator Super-Cap...
...The Array Accelerator Cache will be enabled once Super-Cap is installed and charged.
Audible Beeps: None
Possible Cause: The Array Accelerator Super-Cap needs to be installed.
Action: Install the Array Accelerator Super-Cap.
1802-Slot X Drive Array - Dual domain configured or detected but not supported by
this configuration
Audible beeps: None
Possible cause: A dual domain has been configured or detected, but is not supported.
Action: Perform one of the following:
Remove the extra cabling and shift back to single domain.
Upgrade the controller/SAAP license to enable dual domain.
1803-Slot X Drive Array - Cache Module is not installed;...
IMPORTANT: Unsupported Configuration: Controller performance and supported configurations are limited.
Action: Install the Cache Module to remove these limitations.
Audible Beeps: None
Possible Cause: The Cache Module is not installed.
Action: Install the Cache Module to remove the limitations.
1804-Slot X Drive Array - Cache Module critical error...
Action: Replace Cache Module (Controller is disabled until this problem is resolved).