3. When running HP SUM on Windows, if the iLO Channel Interface Driver is not installed, the iLO
FW will show a version of 'None' as the installed version and 'Ready for Installation' as the status
on the Select Bundle or Select Component page. This applies to firmware for iLO 2, 3, and 4.
When you try to update the firmware, it might not update if it is already up to date.
4. Broadcom NICs are not discovered by HP SUM unless the appropriate driver is installed and all
Ethernet ports are up. You can bring up the Ethernet port by using the following command:
# ifup ethx
or
# ifup ethx up
To update the firmware for Broadcom NIC, use the following steps:
• Install the appropriate Windows or Linux driver found in the SPP. If updating a Linux server,
the driver can also be retrieved from the SDR or the Linux distro.
• Enable all the Ethernet ports
• Run the Broadcom FW upgrade component
When updating Windows Server 2012 systems using HP SUM, HP Storage Brocade Storport Fibre
Channel Host Bus Adapter Driver for Microsoft Windows Server 2012 R2 and HP Firmware Online
Flash for Brocade Fibre Channel Host Bus Adapters - Windows Server 2012 R2 (x64), might incorrectly
appear as available for update
When updating Windows Server 2012 (non-R2) systems using HP SUM, the following components
might incorrectly appear as available for deployment and two driver components and two firmware
components might be shown in the HP SUM GUI as available for deployment on Windows 2012
target nodes. Those components are the HP Storage Brocade Storport Fibre Channel Host Bus Adapter
Driver for Microsoft Windows Server 2012 R2 and the HP Firmware Online Flash for Brocade Fibre
Channel Host Bus Adapters - Windows Server 2012 R2 (x64). For Microsoft Windows Server 2012
(non-R2) target nodes, select: Driver 3.2.1.0, cp019320 Firmware 2013.08.01, cp019374 Deselect:
Driver 3.2.3.1, cp021773 Firmware 2013.11.01, cp022023.
Changing the default location of the HP SUM temporary files
Use one of the following methods to change the default location where HP SUM stores temporary files:
• Create the directory /tmp/HPSUM (Linux) or %temp%/HPSUM (Windows). Create a symbolic link
to the directory where you want the files to be stored before launching HP SUM. HP SUM stores
all temporary files in the specified directory.
• Place a version of the hpsum.ini file in the directory from which you launch HP SUM. Add the
following lines:
[Engine]
temp_dir=<directory path>/
HP SUM places all temporary files in the specified directory except for the binary.log.
NOTE: For all systems, the path must include the / delimiter.
HP SUM takes longer than expected to deploy updates to multiple nodes
Suggested Action: Update a maximum 10 notes from the GUI and a maximum 20 nodes by input file.
HP SUM session issues
HP SUM displays a certificate warning when connecting to HP SUM from a remote browser.
HP SUM versions 6.0.1, 6.2.0, and 6.3.0 contain a certificate that expires in 2016.
18 Issues and suggested actions