HP Smart Update Manager 6.4.1 Release Notes

Suggested action: HP SUM is unable to open the firewall in all instances. These include: third-party
firewall applications, Linux iptables DROP entries, and firewalls with complex rules. When the
open_firewall command does not work, manuallyopen the firewall and then HP SUM can manage
the node.
HP SUM does not deploy IPDU nodes if the same version of the firmware is already installed
Suggested action: No action. This will be resolved in a future version.
Baseline issues
HP SUM only includes firmware updates when you use the device option filter to create a custom
baseline
Description: HP SUM does not include software updates if you select the following options:
Component Type: Both or Software.
Device Type: Any device type you select from the list.
Suggested Action: No action necessary. This will be fixed in a future version.
HP SUM does not deploy Brocade switch firmware updates greater than 7.2.0 if MAPS is enabled
Suggested Action: Disable MAPS before upgrading firmware to versions greater than 7.2.0.
HP SUM unexpectedly quits running if it tries to pull a component from the web that does not exist
Suggested Action: No action. This will be resolved in a future version.
HP SUM displays different component counts between a local baseline and one pulled from the web
Suggested Action: No action. Some components are unpublished after the SPP is released, and HP
SUM does not download those components.
HP SUM reports incorrectly that a baseline was not deleted in Console mode
Suggested Action: No action necessary. This will be fixed in a future version. This occurs if the baseline
you are deleting is in the same directory as additional packages that are not in the baseline.
HP SUM does not assign the baseline for a node when added by IP range
Suggested Action: Edit the node after it has been added to assign the baseline. This will be resolved
in a future version.
HP SUM quits working when you delete a baseline
Suggested Action: Wait until HP SUM finishes performing inventory on a baseline before you delete
the baseline.
HP SUM does not display some RPM components in a baseline
Suggested Action: Update the component from another tool.
HP SUM does not correctly report the number of updates downloaded from the HP website
Suggested Action: No action. This will be resolved in a future version.
HP SUM does not display a downloaded baseline when you try to assign it to a node
Suggested Action: No action. This will be resolved in a future version.
24 Issues and suggested actions