Power Sequencing
Be sure to power up the cluster components in the following order:
1. RA4000/RA4100 Arrays
2. Storage Hubs, FC-AL Switches, or Fibre Channel SAN Switches
(Power is applied to a Storage Hub when the AC power cord is
plugged in.)
3. Ethernet hubs or switches
4. ProLiant servers
Be sure to power down the cluster components in the following order:
1. ProLiant servers
2. Ethernet hubs or switches
3. Storage Hubs, FC-AL Switches, or Fibre Channel SAN Switches
(Power is applied to a Storage Hub when the AC power cord is
plugged in.)
4. RA4000/RA4100 Arrays
Shutting down and powering off the servers first allows them to perform tasks
such as flushing queued database write transactions to disk and properly
terminating running processes.