Compaq Parallel Database Cluster Model PDC/O1000 for Oracle8i and Windows 2000 Administrator Guide
2-20 Compaq Parallel Database Cluster Model PDC/O1000 for Oracle8i and Windows 2000 Administrator Guide
Compaq Confidential – Need to Know Required
Writer: John Blackburn Project: Compaq Parallel Database Cluster Model PDC/O1000 for Oracle8i and Windows 2000 Administrator Guide
Comments:
Part Number: 225083-002 File Name: c-ch2 Cluster Architecture.doc Last Saved On: 6/11/01 11:20 AM
Maximum Distances Between Cluster Nodes and
Shared Storage Subsystem Components in a
Non-Redundant FC-AL
By using standard short-wave Fibre Channel cables and GBIC-SW modules,
an RA4000/RA4100 Array can be placed up to 500 meters from the Storage
Hub or FC-AL Switch, and the Storage Hub or FC-AL Switch can be placed
up to 500 meters from the Fibre Host Adapter in each cluster node. See
Figure 2-9.
500 m
500 m
500 m
500 m
500 m
Storage Hub/FC-AL Switch
RA4000/4100 Array
Node 1Node 3
Node 2 Node 4
Figure 2-9. Maximum distances between cluster nodes and shared
storage components in a non-redundant FC-AL
I/O Data Paths for a Non-Redundant FC-AL
The shared storage components in a non-redundant FC-AL use two distinct
I/O data paths, separated by the Storage Hub or FC-AL Switch:
■ One path runs from the Fibre Host Adapter in each node to the Storage
Hub or FC-AL Switch.
■ Another path runs from the Storage Hub or FC-AL Switch to the
RA4000 Array Controller in each RA4000/RA4100 Array of that
non-redundant FC-AL.