Compaq Parallel Database Cluster Model PDC/O1000 for Oracle8i and Windows 2000 Administrator Guide
Installation and Configuration 5-11
Compaq Confidential – Need to Know Required
Writer: Carol Tatick Project: Compaq Parallel Database Cluster Model PDC/O1000 for Oracle8i and Windows 2000 Administrator Guide Comments:
Part Number: 225083-002 File Name: f-ch5 Installation and Configuration.doc Last Saved On: 6/11/01 12:06 PM
Figure 5-3 shows a PDC/O1000 with two non-redundant Fibre Channel
Fabrics or two non-redundant FC-ALs. The hardware for the second Fibre
Channel Fabric or FC-AL is shaded.
NOTE: You can mix non-redundant Fibre Channel Fabrics and non-redundant FC-ALs in
the same PDC/O1000 cluster.
Storage Hubs/Switches
RA4000/4100
Arrays (8)
RA4000/4100
Arrays (4)
Fibre
Host Adapters
Fibre
Host Adapters
Figure 5-3. PDC/O1000 cluster with two non-redundant Fibre Channel Fabrics
or non-redundant FC-ALs
Cabling the Ethernet Cluster Interconnect
A PDC/O1000 running Oracle8i software is an Ethernet cluster interconnect.
The following components are used in a non-redundant Ethernet cluster
interconnect:
■ One Ethernet adapter in each cluster node
■ Ethernet cables and a switch or hub
G For two-node PDC/O1000 clusters, you can either use one Ethernet
crossover cable or one 100-Mbit/second Ethernet switch or hub and
standard Ethernet cables to connect the two servers.
G For PDC/O1000 clusters with three or more nodes, you use one
100-Mbit/second Ethernet switch and standard Ethernet cables to
connect the servers.