ProLiant DL580 Generation 3 Server Maintenance and Service Guide
Table Of Contents
- HP ProLiant DL580 Generation 3 Server Maintenance and Service Guide
- Notice
- Contents
- Illustrated parts catalog
- Removal and replacement procedures
- Required tools
- Safety considerations
- Preparation procedures
- Removing the front bezel
- Removing a media drive blank
- Removing a media drive
- Removing the processor module
- Removing a processor
- Removing a PPM
- Removing a PCI latch
- Removing a PCI retaining clip
- Removing the PCI-X Hot Plug basket
- Removing a non-hot-plug expansion board
- Removing the PCI-X Hot Plug mezzanine option
- Removing the PCI Express mezzanine option
- Recovering data from the BBWC
- Removing the BBWC battery pack
- Removing the BBWC cache module
- Removing the system board
- Removing the system battery
- Removing the media board
- Removing the SCSI backplane
- Removing the power backplane
- Removing the memory backplane
- Removing a hard drive blank
- Removing a hot-plug SCSI hard drive
- Removing a hot-plug SAS hard drive
- Removing the SAS-SATA hard drive cage
- Removing the SAS-SATA backplane
- Removing a PCI-X Hot Plug expansion board
- Removing a power supply blank
- Removing a redundant hot-plug power supply
- Replacing hot-plug fans
- Memory overview
- Diagnostic tools
- SmartStart software
- SmartStart Scripting Toolkit
- HP Instant Support Enterprise Edition
- Option ROM Configuration for Arrays
- HP ROM-Based Setup Utility
- ROMPaq utility
- System Online ROM flash component utility
- Integrated Management Log
- Integrated Lights-Out technology
- Automatic Server Recovery
- HP Systems Insight Manager
- HP Insight Diagnostics
- USB support
- Troubleshooting the system using port 85 codes
- Server component identification
- Front panel components
- Front panel LEDs and buttons
- Memory board components and LEDs
- Processor module LEDs
- Rear panel components
- Rear panel LEDs and buttons
- Power supply LEDs
- System board components
- DIMM slot locations
- SCSI IDs
- Hot-plug SCSI hard drive LEDs
- Hot-plug SCSI hard drive LED combinations
- SATA or SAS IDs
- SATA or SAS hard drive LEDs
- SAS and SATA hard drive LED combinations
- Fan locations
- Hot-plug fan LEDs
- BBWC LEDs
- Server cabling
- Specifications
- Acronyms and abbreviations
- Index

Removal and replacement procedures 33
IMPORTANT: HP recommends troubleshooting the system using port 85 codes before replacing the system
board. Refer to "Troubleshooting the system using port 85 codes (on page 64)" for a list of codes and
troubleshooting procedures.
1. Power down the server (on page 16).
2. Remove all media drives ("Removing a media drive" on page 19) and media drive blanks
("Removing a media drive blank" on page 19).
3. Remove all hard drives ("Removing a hot-plug SCSI hard drive" on page 40, "Removing a hot-plug
SAS hard drive" on page 41) and hard drive blanks ("Removing a hard drive blank" on page 40).
4. Remove all memory boards ("Removing a memory board" on page 58, "Removing a memory board
(non-hot-plug)" on page 57) and memory board blanks.
5. Remove the processor module ("Removing the processor module" on page 20).
6. Extend or remove the server from the rack ("Remove the server from the rack" on page 16).
7. Remove the access panel ("Removing the access panel" on page 17).
8. Remove the media board ("Removing the media board" on page 37).
9. Remove the SCSI backplane ("Removing the SCSI backplane" on page 37).
10. Remove all system fans ("Replacing hot-plug fans" on page 49).
11. Remove all expansion boards ("Removing a non-hot-plug expansion board" on page 28, "Removing
a PCI-X Hot Plug expansion board" on page 47).
12. Remove the PCI-X Hot Plug basket ("Removing the PCI-X Hot Plug basket" on page 28), if installed.
13. Disconnect the cable from the PCI-X Hot Plug mezzanine board, if installed.
14. Remove the system cage ("Removing the system cage" on page 17).
15. Unlock the latch and open the lever.